The following CLI commands are used to input CIR data:
CLI> define fr tunnel
The following is a list of options that are used to configure CIR data:
Example:
CLI> define fr tunnel maxRxCIR
| Parameter | Range of Values | Required Action |
|---|---|---|
| <IfIndex> | INTEGER (1..255) | Enter the TunnelIfIndex of the netlink established in Step 10 of CLI Procedure for Configuring Physical Ports and DLCIs. |
| <maxRxCIR> | INTEGER (0..256000) | Enter the maximum receive CIR for this PVC tunnel. |
Example:
CLI> define fr tunnel maxRxCIR 15 553
| |
Note: Maximum receive/transmit is the maximum receive/transmission rate of the frame size sent out through the PVC tunnel. |
Save the configuration of the Passport 4400 and restart the unit.
CLI> save configuration update
CLI> reset system current reset
End of Procedure
End of Topic
End of CLI procedures for Configure Passport Connections