Configuration Procedure for Input of Variables for the PANL-DTE Connection

Use the following Configurator procedure to input variables for the PANL-DTE connection:

  1. To configure PANL-DTE connections, select Configure, WAN/Data Services, and PANL.
  2. You will see the Port Selection (PANL) window.

  3. At the top of the window, select DTE PANL Links. You will see the DTE PANL Links window:
  4. Click Modify next to the Index you want to configure. You will see the DTE PANL Link Configuration window:
  5. The table below describes the required parameters:

    Parameter

    Range of Values

    Required Action

    Sub-Channel DLCI

    INTEGER (17 - 255)

    Enter the maximum number of DLCI you want configured for the Passport 4400 unit. The default for this parameter is 47 (63-16). If you think that you will need more than 47 DLCIs, change this parameter to fit your needs.

    DTE Rx Bandwidth

    INTEGER (16000 - 204800)

    Enter the same value that the CIR parameter of the Passport 4400 unit is set to. See Configurator Procedure for Input of Committed Information Rate (CIR) Data.

    DCE Rx Bandwidth

    INTEGER (16000 - 204800)

    Enter the same value that the CIR parameter of the Passport 4400 unit is set to. Configurator Procedure for Input of Committed Information Rate (CIR) Data.

    Max. DTE Frame Size

    INTEGER (50 - 4100)

    Enter the maximum size (in bytes) of frames received by the PANL-DTE. To ensure proper flow of voice packets, set these parameters to (baud/64000) * 80, where baud is the baud rate of the physical WAN port as selected in Step 4 of Configurator Procedure for Configuring Physical Ports and DLCIs.

    Max. DCE Frame Size

    INTEGER (50 - 4100)

    Enter the maximum size (in bytes) of frames received by the PANL-DTE. To ensure proper flow of voice packets, set these parameters to (baud/64000) * 80, where baud is the baud rate of the physical WAN port as selected in Step 4 of Configurator Procedure for Configuring Physical Ports and DLCIs.


  6. Click Save. A "Command Successful" appears.

You must reset the system before the new configuration will take effect. Go to Save the Current Configuration and Reset the Unit for the steps necessary to save your new configuration.