Configurator Procedure for Configuring a 56k CSU Interface

To set the 56k CSU parameters, use the following Configurator steps:

  1. Complete Steps 1 through 3 of Configurator Procedure for Configuring a T1 CSU or E1 CSU Interface.
  2. Select 56k. You will see the Physical Interface (56k CSU) window.
  3. Use the pull down menu to select the applicable port you want to configure the 56K CSU interface on. You will see the 56K CSU window:
  4. Refer to the table below for a description of Configurator options for configuring a 56k CSU interface:

    Options

    Description

    Idle Mode

    Used to select transmission of the All Marks (or 1s) of the Data Mode Idle sequence for all modes. Options are Disable and Enable.

    Tx Condition

    Used to select transmission of the 56k CSU Control Mode Idle sequence. Options are Normal and Idle.

    Default = Normal.

    Clock Source

    Sets the clocking source to External and Internal clock.

    Default = External.

    Out of Service Tx

    Used to select transmission of the Out Of Service sequence for the DDS-PRI mode, or transmission of the Abnormal Station Code sequence for the DDS-SC mode. Options are Disable and Enable.

    Zero Suppression

    Enables or disables transmit zero suppression for DDS-PRI mode, or the transmission of all zeros for DDS-SC mode. Options are On and Off.

    Loopback

    Used to force the CSU to be in loopback mode. Options are Disable and Enable.


  5. After you have completed inputting the parameters, click Save. A "Command Successful" appears.

End of Procedure

End of Topic

CLI Procedure for Configuring a 56k CSU Interface

End of Configurator procedures for Alternate WAN Modules