show csu 56K status (entry/table)

Use show csu 56K status to show the 56K CSU status and statistics table.

You must enter the IfIndex in order to display an individual entry: (One entry is shown when you use the entry option and the full table of entries is shown when you use the table option.)

Object

Parameter

<IfIndex>

: INTEGER (1..255)


A table similar to the following is displayed:

IfIndex

:156

56kLineStatus

:linkDown

RxLossOfSignal

:yes

FAWSyn

:no

LoopPresent

:no

RxInsertionLoss

:iL50pt5db-LL8pt5km

RxSignalMagnitude

:84

InvalidBPVCount

:157


IfIndex

The IfIndex value of the specifc 56K CSU entry.

56kLineStatus

Shows the 56K CSU line status. Variables are operational, linkdown and testMode.

RxLossOfSignal

Shows if the 56K CSU receiver has lost signal. Variables are yes and no.

FAWSyn

Shows the 56K CSU DDS FAW Sync in DDS-SC or CC-64K. Variables are yes and no.

LoopPresent

Shows if the 56K CSU loop is currently present. Variables are yes and no.

RxInsertionLoss

Shows the 56 CSU receiver Insertion loss (iL) in db, and Line Length (LL) in kilometers.

RxSignalMagnitude

Shows the 56K CSU receive signal magnitude expressed as the 'receiver slicer level'.

InvalidBPVCount

Shows the 56K CSU invalid BPV (Bipolar Violation) count. Note that this is an 8-bit counter.