Go back one pageGo to the next page#Go to this book's Table of ContentsGo to this book's Index#


show lapb parameters (configured/operational) (entry/table)

Use show lapb parameters configured to display configuration information about the parameters that have been entered, but are not necessarily in use in the LAPB interface. Use show lapb parameters operational to display configuration information about the parameters currently set in the LAPB interface.

You must enter the Index in order to display an individual entry: (One entry is shown when you use the entry option and the full table of entries is shown when you use the table option.)

Object

Parameter

<Index>

: INTEGER (1..255)


A table similar to the following is displayed:

Index

:20

LowerInterface

:180

TransmitKWinSize

:7

ReceiveKWinSize

:7

RxmitCount

:20

T1AckTimer

:3000

T2AckDelayTimer

:100

T3DisconnectTimer

:60000

T4IdleTimer

:60000

BusyTimer

:10000

StationType

:dce

Sequencing

:modulo8


Index

The ifIndex value for the LAPB interface.

LowerInterface

This object identifies the ifIndex of the interface immediately below this interface (ie. physical or virtual port). A value of 0 indicates that this LAPB instance is not assigned to an underlying port.

TransmitKWinSize

The current PDU window size this interface uses to transmit. This is the maximum number of unacknowledged sequenced PDUs that may be outstanding from this DTE at any one time.

ReceiveKWinSize

The current receive PDU window size for this interface. This is the maximum number of unacknowledged sequenced PDUs that may be outstanding from the DCE remote DTE at any one time.

RxmitCount

The current N2 retry counter used for this interface. This specifies the number of times a PDU will be resent after the T1 timer expires without an acknowledgement for the PDU.

T1AckTimer

The current T1 timer for this interface. This specifies the maximum time in milliseconds to wait for acknowledgment of a PDU.

T2AckDelayTimer

The current T2 timer for this interface. This specifies the maximum time in milliseconds to wait before sending an acknowledgment for a sequenced PDU.

T3DisconnectTimer

The current T3 timer for this interface. This specifies the time in milliseconds to wait before considering the link disconnected. A value of zero indicates the link will be considered disconnected upon completion of the frame exchange to disconnect the link.

T4IdleTimer

The current T4 timer for this interface. This specifies the maximum time in milliseconds to allow without frames being exchanged on the data link. A value of 2147483647 indicates no idle timer is being kept.

BusyTimer

Duration to wait before transmitting an RR frame after receiving an RNR from the remote peer.

StationType

Identifies the desired station type of this interface.

Sequencing

This value identifies the modulus to be used for LAPB sequence numbers.



Nortel Networks LogoContact us by email
Go back one pageGo to the next page#Go to this book's Table of ContentsGo to this book's Index