Go back one pageGo to the next page#Go to this book's Table of ContentsGo to this book's Index#


add fr switch map

Use add fr switch map to define the frame relay switch map. SwitchType must be specified as either frame relay Data Communications Equipment (DCE), HDLC transparent data service (HTDS), cbr, x.25 or sna-sdlc.

Object 

Parameter

Description

<LocalNetIfIndex>

:INTEGER (1..255)

Indicates the IfIndex of the frame relay service.

<LocalNet>

:INTEGER (16..991)

Indicates the Data Link Connection Identifier (DLCI) for the Frame Relay Data Communications Equipment (FRDCE) service on the local Passport 4400 unit.

<RemoteNet>

:INTEGER (16..991)

Indicates the for the FRDCE service on the remote Passport 4400 unit.

<SVCDNA>

:Frame Relay DNA (as a quoted string) (1..34)

The required string includes the DNA prefix of the remote Passport 4400 unit, followed by the number 3, indicating the frame relay service provider, followed by the Slot number and the PPA number of the physical port on the remote Passport 4400 unit (inside quotation marks without any spaces).

<ConnectType>

:slave | master

Choose master for the site that will establish the connection. Choose slave for the other site. When establishing a switch map from a Passport 4400 to a Passport 6400, the Passport 4400 should always be set to master.

<SwitchType>

:frdce | htds | cbr | x25*

 

*The x25 option is only available on the Passport 4430/4450/4455 units.

Both ends of the connection must have the same SwitchType.


Note

Note: If you want to change an entry made using the add fr switch map command, you must first delete the existing entry prior to adding a new entry. Use the delete fr switch map command to delete the first entry.



Nortel Networks LogoContact us by email